EMISSION SOURCES - MAXIMUM ALLOWABLE EMISSION RATES
Permit Numbers 70492 and PSD-TX-1037

This table lists the maximum allowable emission rates and all sources of air contaminants on the applicant's property covered by this permit. The emission rates shown are those derived from information submitted as part of the application for permit and are the maximum rates allowed for these facilities. Any proposed increase in emission rates may require an application for a modification of the facilities covered by this permit.

PM/PM10 0.10
AIR CONTAMINANTS DATA
      Emission Rates **
Emission
Point No. (1)
Source
Name (2)
Air Contaminant
Name (3)
lb/hr TPY*





U-6 Spruce Power Generating
Unit No. 2 (8,000 MMBtu/Hr)
NOX 1600 1752
    SO2 2880 2102
    264 771
    CO 4480 5256
    VOC 29 88
    H2SO4 44 129
    NH3 50 66
    HF 60 26
    HCl 480 66
    Pb 0.2 0.3
    Hg 0.43 0.07
U-6, U-5, E-3, E-1, E-2 Emissions Cap for Spruce Unit 1 & 2, Deely Units 1 & 2, and Sommers 1 & 2 (5) NOx --- 10454
U-6, U-5 Emissions Cap for Spruce Unit 1 & 2 (5) SO2 --- 4319
EMGEN-1 Emergency Generator 1 NOX 38.6 1.2
    SO2 1.3 0.04
    PM/PM10 1.1 0.03
    CO 8.9 0.3
    VOC 1.1 0.03
EMGEN-2 Emergency Generator 2 NOX 38.6 1.2
    SO2 1.3 0.04
    PM/PM10 1.1 0.03
    CO 8.9 0.3
    VOC 1.1 0.03
T-ACID Sulfuric Acid Storage Tank H2SO4 <0.01 <0.01
T-BASE Base Storage Tank Bases <0.01 <0.01
F-NH3 Aqueous Ammonia Fugitives NH3 0.47 2.1
FAS3 Fly Ash Silos for Spruce Unit 1 PM 0.527 0.247
    PM10 0.178 0.083
    Pb 1.1E-04 3.5E-05
    Hg 4.5E-06 5.9E-07
FAS4 Fly Ash Silos for Spruce Unit 2 PM 0.689 0.322
    PM10 0.235 0.110
    Pb 1.4E-04 4.5E-05
    Hg 5.9E-06 7.7E-07
EAS4 Economizer Ash Silos for
Spruce Unit 2
PM 0.103 0.160
    PM10 0.100 0.156
    Pb 2.1E-05 2.3E-05
    Hg 8.8E-07 3.8E-07
FAD3 Spruce Unit 1 Fly Ash Loadout
to Trucks
PM 0.31 0.21
    PM10 0.075 0.05
    Pb 2.6E-06 3.0E-05
    Hg 2.6E-06 5.0E-07
FAD4 Spruce Unit 2 Fly Ash Loadout
to Trucks
PM 0.31 0.29
    PM10 0.08 0.10
    Pb 6.2E-05 4.0E-05
    Hg 2.6E-06 6.8E-07
EAD4 Spruce Unit 2 Economizer Ash Loadout
to Trucks
PM 0.01 0.0004
    PM10 0.01 0.0004
    Pb 1.1E-06 5.7E-08
    Hg 4.5E-08 9.7E-10
F-FILL Sludge and Ash Landfill
Fugitives
PM 1.53 6.8
    PM10 0.76 3.38
    Pb 1.2E-05 5.4E-05
    Hg 2.1E-07 9.2E-07
F-LS Limestone Receiving and Handling
Fugitives
PM 0.004 0.0006
    PM10 0.002 0.0003
A-L55 Limestone Storage Pile PM 0.08 0.35
    PM10 0.04 0.18
LDC-12 Limestone Receiving Baghouse PM 1.2E-02 1.7E-03
    PM10 5.6E-03 8.2E-04
LDC-10 Limestone Silos PM 1.2E-02 1.7E-03
    PM10 5.6E-03 8.1E-04
F-CCS Coal Storage Fugitives PM 9.08 39.7
    PM10 1.88 8.2
PX-CO1A/B Railcar No.1 Unloading and
Transfer Baghouse
PM 0.01 0.02
    PM10 0.01 0.02
PX-CO2 Railcar No.1 Unloading Fugitives PM 0.25 0.53
    PM10 0.05 0.11
DC-15 Railcar No.2 Unloading and
Transfer Baghouse
PM 0.01 0.02
    PM10 0.01 0.02
PX-CO3 Railcar No.2 Unloading Fugitives PM 0.25 0.53
    PM10 0.05 0.11
PX-CO4 Rotary Plow Reclaim PM 0.24 0.05
    PM10 0.05 0.01
PX-C16 Stacker/Reclaim - Stackout PM 0.47
    PM10 0.10 0.021
PX-C17 Stacker/Reclaim - Reclaim PM 0.807 0.303
    PM10 0.17 0.06
F-Area1 Coal Conveyor Fugitives -
Coal Yard Area
PM 0.96 1.23
    PM10 0.20 0.25
F-Area 2 Coal Conveyor Fugitives -
Transfer Area
PM 0.11 0.11
    PM10 0.02 0.02
F-Area 3 Coal Conveyor Fugitives - J.K.
Spruce Power Island
PM 0.19 0.17
    PM10 0.04 0.04
DC-1 Transfer Building 1 PM 0.016 0.034
    PM10 0.003 0.007
DC-2 South Reclaim Hopper to
Conveyor 4
PM 0.090 0.134
    PM10 0.019 0.028
DC-3 Transfer Building 1a PM 0.02 0.04
    PM10 0.004 0.008
DC-CCG016 Crusher Building 1 PM 0.20 0.75
    PM10 0.041 0.155
DC-4A Silo Group A Headhouse PM 0.024 0.04
    PM10 0.005 0.008
DC-4B Silo Group A Unloading PM 0.008 0.013
    PM10 0.002 0.003
DC-5 Crusher Building 2 PM 0.30 0.75
    PM10 0.062 0.155
DC-6 North Reclaim Hopper to
Conveyor 23B
PM 0.09 0.134
    PM10 0.019 0.028
DC-7 Transfer Building 4 PM 0.007 0.017
    PM10 0.00 10.003
DC-9 Transfer Building 6 PM 0.007 0.005
    PM10 0.001 0.001
DC-10 Transfer Building 7 PM 0.007 0.002
    PM10 0.001 0.001
DC-11 Silo Group B Headhouse PM 0.016 0.027
    PM10 0.003 0.006
DC-12 Silo Group B Loadout PM 0.008 0.013
    PM10 0.002 0.003
DC-13 Transfer Building 9 PM 0.008 0.013
    PM10 0.002 0.003
DC-14 Transfer Building 1B PM 0.008 0.013
    PM10 0.002 0.003
DC-101 Unit 1 Transfer Building 5
and Tripper Deck
PM 0.013 0.006
    PM10 0.003 0.001
DC-201 Unit 2 Transfer Building 8 and
Tripper Deck
PM 0.013 0.005
    PM10 0.003 0.001
T3 Emergency Generator No. 1
Fuel Tanks
VOC 2.3 5.82
T4 Emergency Generator No. 2
Fuel Tanks
VO C2.3 5.82

EMISSION SOURCES - MAXIMUM ALLOWABLE EMISSION RATES

  1. Emission point identification - either specific equipment designation or emission point number from plot plan.
  2. Specific point source name. For fugitive sources use area name or fugitive source name.
  3. VOC-volatile organic compounds as defined in 30 Texas Administrative Code Section 101.1 PM-particulate matter, suspended in the atmosphere, including PM10. PM10-particulate matter equal to or less than 10 microns in diameter. Where PM is not listed, it shall be assumed that no particulate matter greater than 10 microns is emitted. NOX-total oxides of nitrogen SO2-sulfur dioxide NH3-ammonia CO-carbon monoxide H2SO4-sulfuric acid mist Pb-lead HCl-hydrogen chloride HF-hydrogen fluoride Hg-mercury
  4. Fugitive emissions are an estimate only.
  5. The cap becomes effective upon start-up of Spruce 2 Utility Boiler.

*Compliance with annual emission limits is based on a rolling 12-month period.

**Emission rates are based on and the facilities are limited by the following maximum operating schedule:

*Emission rates are based on the following operating schedule: